Rule-Mate® Tam Otomatik Sintine Pompası

Model: RM1500A - Kapasite (GL/Saat): 1500 - Volt: 12V - Amp @ 12V: 4.8 - Sigorta: 10A - Hortum Ø: 25mm (1“) veya 29mm (1…

₺14.511,34

Rule-Mate® Tam Otomatik Sintine Pompası

Model: RM800B - Kapasite (GL/Saat): 800 - Volt: 24V - Amp @ 24V: 1.4 - Sigorta: 4A - Hortum Ø: 3/4“(19 mm) - Yükseklik:…

₺9.282,99

Rule-Mate® Tam Otomatik Sintine Pompası

Model: RM800B - Kapasite (GL/Saat): 800 - Volt: 12V - Amp @ 12V: 2..8 - Sigorta: 5A - Hortum Ø: 3/4“(19 mm) - Yükseklik:…

₺6.584,98

Rule-Mate® Tam Otomatik Sintine Pompası

Model: RM500B - Kapasite (GL/Saat): 500 - Volt: 12V - Amp @ 12V: 2..0 - Sigorta: 3A - Hortum Ø: 3/4“(19 mm) - Yükseklik:…

₺4.999,70

Rule® Sintine pompası

Model: 56D-24 - Kapasite (GL/Saat): 4000 - Volt: 24V - Amp @ 24V: 6.9 - Sigorta: 15A - Hortum Ø: 2“ (51 mm) - Yükseklik:…

₺12.804,12

Rule® Sintine pompası

Model: 16A - Kapasite (GL/Saat): 3700 - Volt: 24V - Amp @ 24V: 6.9 - Sigorta: 15A - Hortum Ø: 1 1/2“ (38 mm) - Yükseklik…

₺11.828,57

Rule® Sintine pompası

Model: 12 - Kapasite (GL/Saat): 2000 - Volt: 24V - Amp @ 24V: 4 - Sigorta: 7.5A - Hortum Ø: 1 1/8“ (29 mm) - Yükseklik:…

₺8.170,25

Rule® Sintine pompası

Model: 10 - Kapasite (GL/Saat): 2000 - Volt: 12V - Amp @ 12V: 7.3 - Sigorta: 15A - Hortum Ø: 1 1/8“ (29 mm) - Yükseklik:…

₺8.170,25

Rule® Sintine pompası

Model: 03 - Kapasite (GL/Saat): 1500 - Volt: 24V - Amp @ 24V: 2.3 - Sigorta: 4A - Hortum Ø: 1 1/8“ (29 mm) - Yükseklik:…

₺6.097,20

Rule® Sintine pompası

Model: 02 - Kapasite (GL/Saat): 1500 - Volt: 12V - Amp @ 12V: 4 - Sigorta: 10A - Hortum Ø: 1 1/8“ (29 mm) - Yükseklik: 1…

₺6.097,20

Rule® Sintine pompası

Model: 27DA-24 - Kapasite (GL/Saat): 1100 - Volt: 24V - Amp: 1.9 - Sigorta: 3A - Hortum Ø: 1 1/8“ (29 mm) - Yükseklik: 1…

₺3.414,43

Rule® Sintine pompası

Model: 27DA - Kapasite (GL/Saat): 1100 - Volt: 12V - Amp: 3.7 - Sigorta: 6A - Hortum Ø: 1 1/8“ (29 mm) - Yükseklik: 111…

₺3.414,43

Rule® Sintine pompası

Model: 20DA-24 - Kapasite (GL/Saat): 800 - Volt: 24V - Amp: 1.7 - Sigorta: 3A - Hortum Ø: 3/4“ (19 mm) - Yükseklik: 111…

₺4.649,12

Rule® Sintine pompası

Model: 20DA - Kapasite (GL/Saat): 800 - Volt: 12V - Amp: 3.4 - Sigorta: 5A - Hortum Ø: 3/4“ (19 mm) - Yükseklik: 111 mm…

₺3.170,54

Rule® Sintine pompası

Model: 25DA - Kapasite (GL/Saat): 500 - Volt: 12V - Amp: 1.6 - Sigorta: 4A - Hortum Ø: 3/4“ (19 mm) - Yükseklik: 99 mm -…

₺1.951,10

Rule® Sintine pompası

Model: 24DA - Kapasite (GL/Saat): 360 - Volt: 12V - Amp: 2.1 - Sigorta: 2.5A - Hortum Ø: 3/4“ (19 mm) - Yükseklik: 99 mm…

₺1.585,27

Attwood Tsunami sintine pompası.

Model: T800 - Çalışma Voltajı: 12 V - Kapasite: 800 Gl/ Saat - Çıkış Ø: 19 mm (3/4”) - Maksimum Basma Yüksekliği: 4,2 m…

₺1.976,51

Attwood HD2000 Ağır Hizmet Sintine Pompası

Kapasite: 2000 Gl/Saat - Çalışma Voltajı: 24V - Çıkış: Ø 28 mm (1 1/8“) - Maksimum Basma Yüksekliği: 4.9 m - Amper: 7A

₺8.957,80

Attwood HD2000 Ağır Hizmet Sintine Pompası

Kapasite: 2000 Gl/Saat - Çalışma Voltajı: 12V - Çıkış: Ø 28 mm (1 1/8“) - Maksimum Basma Yüksekliği: 4.9 m - Amper: 12A

₺7.179,45

Attwood Tsunami MK2 sintine pompası.

Çalışma Voltajı: 24 V - Kapasite: 1200 Gl/Saat - Çıkış Ø: 19 mm (3/4”) - Sigorta Değeri: 3 A

₺3.043,52

Attwood Tsunami MK2 sintine pompası.

Çalışma Voltajı: 12 V - Kapasite: 1200 Gl/Saat - Çıkış Ø: 25 mm (1”) - Sigorta Değeri: 6 A

₺2.149,26

Attwood Tsunami MK2 sintine pompası.

Çalışma Voltajı: 24 V - Kapasite: 800 Gl/Saat - Çıkış Ø: 19 mm (3/4”) - Sigorta Değeri: 2 A

₺2.962,22

Attwood Tsunami MK2 sintine pompası.

Çalışma Voltajı: 12 V - Kapasite: 800 Gl/Saat - Çıkış Ø: 19 mm (3/4”) - Sigorta Değeri: 5 A

₺2.118,78

Attwood Tsunami MK2 sintine pompası.

Çalışma Voltajı: 12 V - Kapasite: 500 Gl/Saat - Çıkış Ø: 19 mm (3/4”) - Sigorta Değeri: 3 A

₺1.549,71

Bilge: Right Pump, Right Discharge Line, Safer Boat

The bilge is an area in the hull where water can collect, which can affect both comfort and safety when neglected. Small leaks, rainwater, water escaping during washing, condensation or accumulations caused by equipment can accumulate in the bilge over time. As this accumulation increases, problems such as bilge odor, humidity, slipperiness and difficulty in control are experienced more frequently. A robust bilge system aims to manage the water "before the problem grows" with the right pump selection, the right connections and the right control elements.

What does a bilge system do?

  • Water evacuation: Helps to remove water that has accumulated inside the boat.
  • Safety: Supports water containment in case of unexpected water ingress.
  • Comfort: Moisture and odor cycle can be alleviated when accumulation is reduced.
  • Ease of control: A clean and controllable bilge makes it easier to recognize potential problems early.

Choosing the right bilge pump: Electric or manual?

Electric Bilge Pump

Electric bilge pumps are one of the most practical solutions for a boat's layout. Flow requirement, installation area and the structure of the discharge line are decisive in the selection. Together with regular inspection, it provides fast evacuation in routine accumulations.

Automatic Electric Bilge Pumps

If you want "self-activation" when you are not at the boat, automatic electric bilge pumps may be the right approach. Automatic operation aims for a safer routine with correct installation and periodic inspection.

Manual Bilge Pump

The category of manual bilge pump is important as an electrical stand-alone backup solution or for practical use in specific scenarios. It is a part that increases the durability of the system, especially in a "backup plan" logic.

Automation and control: Floater, switch and alarm

The reassuring part of the bilge system is not only the pump, but also the control components that determine "when it works".

  • Bilge Floater: Used to activate the system when the water level reaches a certain point.
  • Bilge Pump Switch: A practical part on the manual control / circuit management side.
  • Bilge Alarm: It creates the advantage of "early detection" by providing warning in abnormal water level situations.

Drain line Hose, filter/strainer and outlets

No matter how good the pump is, if the discharge line is weak, system efficiency decreases. Therefore, it is necessary to consider hose/filter/outlet parts not as "complementary parts of the pump" but as basic components of the system.

Fugitive and workaround needs: Expansion plugs

In unexpected situations, quick intervention may be required. In such scenarios, expanding plugs are a practical solution that can help provide temporary control (always to be considered in conjunction with the correct diagnosis and permanent repair approach).

Assembly and fittings: Plastic materials

If fasteners, fittings and auxiliary parts are not selected correctly, leakage, loosening or loss of efficiency may occur in the system. It is therefore useful to consider Plastic Materials (for Bilge) as a category that directly affects the "quality of installation".

Practical routine for bilge maintenance (by season)

Beginning of the season

  • Check the pump by running it for a short time; look for blockage/loosening in the line.
  • Check the filter/strainers and clean them if necessary.
  • Test the float and alarm scenario (is the logic correct?).

In-season

  • Visually check the bilge at short intervals; if the accumulation is increasing, investigate the cause.
  • Check hose connections for looseness/leaks.
  • If there is an odor/humidity increase, manage the problem before it escalates.

End of season

  • A good winterization habit is to check the system and leave the bilge clean and "near dry".
  • Review the pieces on the line; enter the next season smoothly.

Common mistakes (short but critical)

  • Think only about the pump: Discharge line, outlets and filter/strainer determine efficiency.
  • Not testing automation: If the floater/alarm is not checked, it may fail unexpectedly.
  • Wrong hose/connection: Increases the risk of leakage and loss of efficiency.
  • Skipping periodic checks: A small problem can turn into a big one.

To summarize: A robust bilge system is a combination of the right pump, the right discharge line and the right control elements. In this category; you can build a more reassuring setup for your boat by evaluating electric bilge pumps, automatic pumps, manual pumps, floats, switches, alarms, hoses/filters/strainers and outlet solutions together.